Geo Direct PWM Amplifier
Power On/Off Procedures 34
POWER ON/OFF PROCEDURES
Caution
Caution
Caution
Powering up the Geo Direct PWM Drive must obey the following procedure:
1. Make sure that PMAC is powered up, and that the PWM cable is connected
2. Apply 24V logic power to the Geo Direct PWM Drive
3. Wait a minimum of ~3 seconds
4. Apply main bus power
5. Wait ~ 3seconds before enabling the drive (motor)
Powering down the Geo Direct PWM Drive must obey the following procedure:
1. Disconnect main bus power
2. Wait a minimum of ~5 seconds
3. Disconnect 24V logic power
Cycling Main Bus Power
Caution
Cycling main bus power must obey the following warning restrictions. A delay should be inserted in
either software, hardware or both to ensure that these restrictions are conformed.