Delta Tau Geo Direct PWM Amplifier Instalační manuál

Procházejte online nebo si stáhněte Instalační manuál pro Audio zesilovače Delta Tau Geo Direct PWM Amplifier. Delta Tau Geo Direct PWM Amplifier Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 53
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
^1 INSTALLATION MANUAL
^2 Geo Direct PWM Amplifier
^3 Direct PWM Amplifier
^4 500-603700-xIxx
^5 November 15, 2013
Single Source Machine Control
……………………………………………..…...……………….
Power // Flexibility // Ease of Use
21314 Lassen St. Chatsworth, CA 91311 // Tel. (818) 998-2095 Fax. (818) 998-7807 // www.deltatau.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 52 53

Shrnutí obsahu

Strany 1 - Geo Direct PWM Amplifier

^1 INSTALLATION MANUAL ^2 Geo Direct PWM Amplifier ^3 Direct PWM Amplifier ^4 500-603700-xIxx ^5 No

Strany 2 - Operating Conditions

Geo Direct PWM Amplifier Specifications 10 480 VAC Drives – Single Axis GxH051 GxH101 GxH151 GxH201 GxH301 Main Input Power Main AC Input [VAC rms]

Strany 3

Geo Direct PWM Amplifier Specifications 11 480 VAC Drives – Dual Axis GxH012 GxH032 GxH052 GxH102 GxH152 Main Input Power Main AC Input [VAC rms] 3

Strany 4 - Table Of Contents 4

Geo Direct PWM Amplifier Receiving and Unpacking 12 RECEIVING AND UNPACKING Delta Tau products are thoroughly tested at the factory and carefully pa

Strany 5 - Table Of Contents 5

Geo Direct PWM Amplifier Mounting, Physical Layout 13 MOUNTING, PHYSICAL LAYOUT The location of the Geo Direct PWM Drive is important. Installation

Strany 6 - INTRODUCTION

Geo Direct PWM Amplifier Mounting, Physical Layout 14 GPx012 Width Height Depth Weight 3.30 in. / 84 mm 11.00 in. / 280 mm 5.80 in. / 147 mm 4.2 lbs

Strany 7 - SPECIFICATIONS

Geo Direct PWM Amplifier Mounting, Physical Layout 15 GPL032 Width Height Depth Weight 3.30 in./ 84 mm 11.00 in./ 280 mm 8.00 in./ 203 mm 5.4 lbs/

Strany 8 - Electrical Specifications

Geo Direct PWM Amplifier Mounting, Physical Layout 16 GPx05x, GPx102, GPL101, GPH032 Width Height Depth Weight 3.30 in./ 84 mm 11.00 in./ 280 mm 8.0

Strany 9

Geo Direct PWM Amplifier Mounting, Physical Layout 17 GPx201, GPx301, GPx152, GPH102 Width Height Depth Weight 6.50 in./ 165 mm 11.00 in./ 280 mm 8.

Strany 10

Geo Direct PWM Amplifier Connector PinOuts and Wiring 18 CONNECTOR PINOUTS AND WIRING WARNING Installation of electrical control equipment is subj

Strany 11

Geo Direct PWM Amplifier Connector PinOuts and Wiring 19 Note AC input wires must be twisted together to eliminate as much noise radiation as poss

Strany 12 - RECEIVING AND UNPACKING

Copyright Information © 2013 Delta Tau Data Systems, Inc. All rights reserved. This document is furnished for the customers of Delta Tau Data Systems

Strany 13 - MOUNTING, PHYSICAL LAYOUT

Geo Direct PWM Amplifier Connector PinOuts and Wiring 20 Three-Phase Main AC Power Wiring Diagram 3-PHASE TRANSFORMER110-240 VACGND L1 L2 L3PROTECT

Strany 14 - Geo Direct PWM Amplifier

Geo Direct PWM Amplifier Connector PinOuts and Wiring 21 Transformers Y-Y or Y- transformers should be used. - Transformers are NOT advised. They

Strany 15 - GPL032

Geo Direct PWM Amplifier Connector PinOuts and Wiring 22 Recommended Bus Power Fuse and Wire Gauge Geo Drive electronics create a DC bus by rectify

Strany 16

Geo Direct PWM Amplifier Connector PinOuts and Wiring 23 J4: 24 VDC Logic Control J4 is used to bring the 24VDC logic power into the Geo Direct PWM

Strany 17

Geo Direct PWM Amplifier Connector PinOuts and Wiring 24 J2 – J3: Motor Wiring The cable wiring must be shielded and have a separate conductor conne

Strany 18 - CONNECTOR PINOUTS AND WIRING

Geo Direct PWM Amplifier Connector PinOuts and Wiring 25 Note The motor thermostats are brought in through connector X3. Motor Cable, Noise Elimin

Strany 19 - Grounding, Bonding

Geo Direct PWM Amplifier Connector PinOuts and Wiring 26 Note Ferrite cores are also commonly used with lower inductance motors to enhance compati

Strany 20

Geo Direct PWM Amplifier Connector PinOuts and Wiring 27 Motor Torque Torque requirements in an application can be viewed as both instantaneous and

Strany 21

Geo Direct PWM Amplifier Connector PinOuts and Wiring 28 J5: External Shunt Resistor J5 is used to wire an external shunt resistor to expel the exce

Strany 22

Geo Direct PWM Amplifier Connector PinOuts and Wiring 29 The black wires are for the thermostat and the white wires are for the shunt resistor. The

Strany 23 - J4: 24 VDC Logic Control

REVISION HISTORY REV. DESCRIPTION DATE CHANGE APPROVAL 1 Added Power On/Off procedures, Power PMAC section, Refurbished entire manual 11/15/2013 RN

Strany 24 - J2 – J3: Motor Wiring

Geo Direct PWM Amplifier Connector PinOuts and Wiring 30 Shunt Resistor Layout

Strany 25

Geo Direct PWM Amplifier Connector PinOuts and Wiring 31 X1 – X2: PWM Connectors This mini D36 connector provides the interface to the PWM output ch

Strany 26

Geo Direct PWM Amplifier Connector PinOuts and Wiring 32 X3: Discrete I/O for Motor Thermals This 6-pin Phoenix Contact terminal block provides conn

Strany 27 - Motor Torque

Geo Direct PWM Amplifier Connector PinOuts and Wiring 33 X4: Safety Relay This 4-pin Phoenix Contact Terminal Block provides connectivity to a safet

Strany 28 - J5: External Shunt Resistor

Geo Direct PWM Amplifier Power On/Off Procedures 34 POWER ON/OFF PROCEDURES Caution Changing the ADC clock on the controller (PMAC) side requires

Strany 29

Geo Direct PWM Amplifier Power On/Off Procedures 35 If the main bus power is removed (i.e. E-Stop condition), it is necessary to keep it off until

Strany 30 - Shunt Resistor Layout

Geo Direct PWM Amplifier PWM Frequency 36 PWM FREQUENCY The minimum PWM frequency of a system is based on the time constant of the motor. In genera

Strany 31 - X1 – X2: PWM Connectors

Geo Direct PWM Amplifier Power PMAC3 Drive Setup 37 POWER PMAC3 DRIVE SETUP Caution The ADC Strobe Word, Gate3[i].AdcAmpStrobe, must be set to $F

Strany 32

Geo Direct PWM Amplifier Power PMAC3 Drive Setup 38 Key Channel Parameters The following channel-specific parameters are essential for the proper so

Strany 33 - TB-4: 016-PL0F04-38P

Geo Direct PWM Amplifier Power PMAC3 Drive Setup 39 Caution Trying to enable the Geo Direct PAM Drive with misreported current data could result i

Strany 34 - POWER ON/OFF PROCEDURES

Geo Direct PWM Amplifier Table Of Contents 4 Table of Contents INTRODUCTION ...

Strany 35 - Power On/Off Procedures 35

Geo Direct PWM Amplifier Power PMAC2 Drive Setup 40 POWER PMAC2 DRIVE SETUP Caution The ADC Strobe Word, Gate1[i].AdcStrobe, must be set to $3FFF

Strany 36 - PWM FREQUENCY

Geo Direct PWM Amplifier Power PMAC2 Drive Setup 41 Key Channel Parameters The following channel-specific parameters are essential for the proper so

Strany 37 - POWER PMAC3 DRIVE SETUP

Geo Direct PWM Amplifier Power PMAC2 Drive Setup 42 Caution Trying to enable the Geo Direct PAM Drive with misreported current data could result i

Strany 38 - Key Channel Parameters

Geo Direct PWM Amplifier Turbo PMAC2 Drive Setup 43 TURBO PMAC2 DRIVE SETUP Caution The ADC Strobe Word, I7m06 ($C014 in Non-Turbo PMAC), must be

Strany 39 - Power PMAC3 Drive Setup 39

Geo Direct PWM Amplifier Turbo PMAC2 Drive Setup 44 Key Channel Parameters The following channel-specific parameters are essential for the proper so

Strany 40 - POWER PMAC2 DRIVE SETUP

Geo Direct PWM Amplifier Turbo PMAC2 Drive Setup 45  I2T Settings, Ixx57, Ixx58, and Ixx69 Example: #define ServoClk 2.258 ; Servo Clock [KHz]—c

Strany 41

Geo Direct PWM Amplifier Drive Command Structure 46 DRIVE COMMAND STRUCTURE Default Mode In default mode, the Geo Direct PWM Drive returns phases A

Strany 42 - Power PMAC2 Drive Setup 42

Geo Direct PWM Amplifier Drive Command Structure 47 Enhanced Mode Enhanced mode enables access to and control of additional functions:  Bus volta

Strany 43 - TURBO PMAC2 DRIVE SETUP

Geo Direct PWM Amplifier Drive Command Structure 48 And the data is found in the lower 12 bits of ADC B for each axis: PMAC Type ADC B data register

Strany 44

Geo Direct PWM Amplifier Troubleshooting 49 TROUBLESHOOTING LED Status LED Description ENABLE 1  Green when axis 1 is enabled  Red when axis 1 is

Strany 45 - Turbo PMAC2 Drive Setup 45

Geo Direct PWM Amplifier Table Of Contents 5 PWM FREQUENCY ...

Strany 46 - DRIVE COMMAND STRUCTURE

Geo Direct PWM Amplifier Troubleshooting 50 Error Codes Display Code Error / Fault Description Description AXIS 1 AXIS 2 Over Current RMS Indicate

Strany 47 - Enhanced Mode

Geo Direct PWM Amplifier Troubleshooting 51 Display Code Error / Fault Description Troubleshooting Notes GLOBAL Normal Mode Operation  No fault

Strany 48 - Drive Command Structure 48

Geo Direct PWM Amplifier Appendix D: Compatible Motors 52 APPENDIX A: CABLE/CONNECTOR KITS PWM Cables Option Cable Length Part Number CABPWM-1 24” (

Strany 49 - TROUBLESHOOTING

Geo Direct PWM Amplifier Appendix D: Compatible Motors 53 Cable Kits Part Number Model Description CABKIT1B Gxx012xx Gxx032xx Gxx052xx GxL102xx Mole

Strany 50 - Troubleshooting 50

Geo Direct PWM Amplifier Introduction 6 INTRODUCTION The Geo Direct PWM amplifiers provide a 1- or 2-axis motor power using highly integrated IGBT b

Strany 51 - Troubleshooting 51

Geo Direct PWM Amplifier Specifications 7 SPECIFICATIONS Part Number Main AC Voltage Input:L = 115 - 230 VACH = 300 - 480 VACNumber of Axes:1 = Sing

Strany 52 - Connector Kits

Geo Direct PWM Amplifier Specifications 8 Electrical Specifications 230 VAC Drives – Single Axis GxL051 GxL101 GxL151 GxL201 GxL301 Main Input Power

Strany 53 - Cable Kits

Geo Direct PWM Amplifier Specifications 9 230 VAC Drives – Dual Axis GxL012 GxL032 GxL052 GxL102 GxL152 Main Input Power Main AC Input [VAC rms] 11

Komentáře k této Příručce

Žádné komentáře