Geo Direct PWM Amplifier
Connector PinOuts and Wiring 32
X3: Discrete I/O for Motor Thermals
This 6-pin Phoenix Contact terminal block provides connectivity to low impedance 12 – 24 VDC motor
thermostat overload detection. This is a normally closed contact, in normal mode operation the Geo direct
PWM Drive expects to see 12 – 24 VDC coming into Pins #1 and #3 respectively for motors 1 and 2.
X3: Phoenix 6-Pin TB Female
Mating: Phoenix 6-pin TB Male
Part Type: FKMC 0,5/6-ST-2,5
Phoenix Contact p/n: 1881367
If nothing is wired fault codes 5 and A are triggered respectively for
motors 1 and 2. Tie MTR PTC and MTR PTC RET to disable this
function.
These contacts can be used for other general purpose safety functions
to kill motor power when desired.