Delta Tau PMAC2 Uživatelský manuál Strana 13

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 41
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 12
Turbo PMAC2 VME Hardware Reference
Bottom Board E-Point Jumper Descriptions 9
E20A-I: DPRAM Byte Order Control
E Point and
Physical Layout
Location Description Default
E20A-I
5 (4 3) (2 1)
5 (4 3) (2 1)
5 (4 3) (2 1)
5 (4 3) (2 1)
5 (4 3) (2 1)
5 (4 3) (2 1)
5 (4 3) (2 1)
5 (4 3) (2 1)
5 (4 3) (2 1)
Jump pins 1 to 2 and pins 3 to 4, to tie DPRAM data
lines 8-15 to VMEbus data lines 8-15, and DPRAM
data lines 0-7 to VMEbus data lines 0-7 (Motorola
big-endian format).
Jump pins 2 to 3 and pins 4 to 5 to tie DPRAM data
lines 8-15 to VMEbus data lines 0-7, and DPRAM
data lines 0-7 to VMEbus data lines 8-15 (Intel little-
endian format).
1-2, 3-4 Jumpers
installed (Motorola
format)
All E20A-I jumpers must be in the same setting for DPRAM communications to work.
E39: Reset-from-Bus Enable
E Point and
Physical Layout
Location Description Default
E39
B5 Jump pin 1 to 2 to permit VMEbus reset line to reset
PMAC2.
Remove jumper so VMEbus reset line does not reset
PMAC2.
1-2 Jumper installed